Language
Home > CKD > Air Pressure Cylinders
Cylinder price COVN2-CA-50B-100-2

CKD Cylinder price COVN2-CA-50B-100-2

Brand:CKD Model:COVN2-CA-50B-100-2

COVN2-CA-50B-100-2 basic valve introduction on how to control the hydraulic cylinder; when the basic valve is powered on, the direct-acting two-position four (five) way solenoid valve directly lifts the iron core valve rod to close the B working port, allowing the pressure source gas or liquid to flow to the A working port, pushing the piston of the pneumatic (hydraulic) cylinder towards the D end ...
COVN2-CA-50B-100-2 basic valve introduction on how to control the hydraulic cylinder; when the basic valve is powered on, the direct-acting two-position four (five) way solenoid valve directly lifts the iron core valve rod to close the B working port, allowing the pressure source gas or liquid to flow to the A working port, pushing the piston of the pneumatic (hydraulic) cylinder towards the D end. This solenoid valve is universal. The pilot-operated two-position four (five) way basic valve relies on the inlet pressure of the pilot port to push the valve rod inside for the direction-changing function of gas (liquid). The pilot-operated two-position four or five way basic valve cannot be used universally in gas and liquid media due to different structures and sealing forms. When the basic valve is powered off, the closing component will return to its original position, and the solenoid valve will close. In this action process, since it is the direct movement of the closed component iron core that achieves the on-off work of the solenoid valve medium, it is also called a basic valve. (Note: normally closed solenoid valve opens when powered on, and normally open solenoid valve closes when powered off is a normally closed solenoid valve, while normally closed solenoid valve closes when powered on, and normally open solenoid valve opens when powered off is a normally open solenoid valve.) The nominal size of the basic valve is not greater than DiVIO, and when the small diameter direct-acting solenoid valve coil is powered on, the magnetic circuit generates electromagnetic force, lifting the moving iron core, overcoming the reset spring force to open the valve seat, allowing the working medium to flow immediately in the pipeline. D4-12AAC-4JA, 411A-B0A-DM-DDAJ-1KD471A-F0A-DM-DDAC-2KD, E-34005-01835A-BCA-DDAA-1BA, MB-A1C-131DMB-DDFJ-1KJ M0D:CLSF, 130B-291JAPPC5C-AAA-AGAA-DAA-HB GY02, 811C-PM-121JM-152MM-P1A-221-A GY02, 34C-ABA-GDFA-1BAMV-P1A-AEDA-DM-DDAP-1DN GY02, 6523B-311-PP-611DAMM-P1A-221-B GY02, 117B-294JA35A-AEA-DAAJ-1KJ M0D:408K, 57D-16-121BA6511D-212-PM-613DA, 55B-12-PI-294JAPME-613DA, 34B-AAA-GDFE-1KA45A-AC1-DABA-1BA, 56C-18-611JA6613A-311-PM-611DA, 35A-AAA-DEDA-1BA M0D:117246A-111-JDA0-1JB, 130B-111JA411A-F0A-GM-GDFA-1KT, 56C-63-A61JB-FM82A-AF-FAA-TU-DDA3-1DA M0D:532B, MV-P1A-ABDA-DM-DDAP-1DN M0D:M96644C-ABA-GDF0-1PB, 57D-36-611JJ23195, 130B-611JAD4-12AGC-4JA, 6631A-

Cylinder price COVN2-CA-50B-100-2 belongs to the Air Pressure Cylinders series under CKD company, model number COVN2-CA-50B-100-2. To purchase or inquire about Cylinder price COVN2-CA-50B-100-2, you can directly contact 158 0047 0089 (Mr. He).

FAQ

  • What is the basic function of CKD pneumatic components?
    CKD pneumatic components use compressed air as a power source to transmit and convert forces. They can be used to control machine movements, transmit force, or achieve automation. Common pneumatic components include cylinders, pneumatic valves, and pneumatic motors.
  • What are the main types of CKD pneumatic components?

    1. Cylinders: Used to convert the energy of compressed air into mechanical energy to produce linear motion.

    2. Pneumatic valves: Used to control the direction, speed, and pressure of airflow, regulating the operation of pneumatic systems.

    3. Pneumatic motors: Devices that convert compressed air into rotary motion.

    4. Air tubes and connectors: Used to connect various components in pneumatic systems and transmit air.

  • Do CKD pneumatic components require regular maintenance? If yes, what are the key points?

    Yes, CKD pneumatic components require regular maintenance to ensure normal operation and extend service life. Key maintenance points include:

    - Regularly check and replace seals and gaskets to prevent air leakage.

    - Inspect and clean filters to ensure clean air quality.

    - Lubricate moving parts to reduce wear and improve efficiency.

    - Check air tubes and connectors to ensure secure and undamaged connections.

  • How to choose the right CKD pneumatic components?

    When selecting the appropriate CKD pneumatic components, consider the following factors:

    Application requirements: Understand the specific working environment and tasks, such as load, speed, and stroke.

    Air source conditions: Ensure that the pressure and flow of the air source meet the component’s requirements.

    Installation space: Confirm available space and choose components of suitable size.

    Environmental factors: Consider the temperature, humidity, and potential corrosiveness of the working environment to select suitable materials and designs.

  • What are common faults in CKD pneumatic component systems and how to troubleshoot?

    Common pneumatic system faults include:

    Air leakage: Causes efficiency decline; check seals, connections, and tubes, find leak points, and repair or replace.

    Stuck cylinder piston: Possibly caused by dirt or insufficient lubrication; clean the piston and add lubricant.

    Valve failure: Check electrical control signals, ensure smooth airflow, and verify if the valve itself is damaged.

    Insufficient pressure: Inspect air source pressure, filters, and piping to ensure no blockage or leakage.

Related Products