Language
Home > CKD > Air Pressure Cylinders
Double-acting cylinder CMK2-00-25-145

CKD Double-acting cylinder CMK2-00-25-145

Brand:CKD Model:CMK2-00-25-145

CMK2-00-25-14 cylinder seal surface is prone to wear, affecting service life. During opening and closing, the gate and valve seat two sealing surfaces slide against each other, and under the action of the medium pressure, it is easy to cause abrasion wear, affecting the sealing performance and shortening the service life. How does the proportional valve work, used to drive VPPE, 9-pin SIE-WD-TR ri ...

CMK2-00-25-14 cylinder seal surface is prone to wear, affecting service life. During opening and closing, the gate and valve seat two sealing surfaces slide against each other, and under the action of the medium pressure, it is easy to cause abrasion wear, affecting the sealing performance and shortening the service life. How does the proportional valve work, used to drive VPPE, 9-pin SIE-WD-TR right-angle socket, used to drive VPPE, aJ quick connector QS for standard outer diameter air tube quick star, aA muffler U for installation at the exhaust port working and environmental conditions, working medium filtered compressed air, unlubricated, filtration level 40 μm, neutral gas, inlet pressure 1 [bar] 7 ... 8, pressure adjustment range [bar] 0.15 ... 6, maximum pressure hysteresis [bar] 0.15, ambient temperature [°C] 10 ... 50, medium temperature [°C] 10 ... 50, corrosion resistance grade CRC 21), CRC2: corrosion resistance level 2, in line with 940 070 standard, components must have a certain corrosion resistance. External visual components have a basic coating surface, can be directly in contact with the industrial environment or with coolants, lubricants and other media. Material housing precision aluminum alloy seal NBR, size CAD related - flow 310 ... 1,250 l/min, -P- voltage 21.6 ... 26.4 V DC, -L- pressure adjustment range 0.02 .0.006, derivative type, set point input is an analog voltage signal 0 ... 10 V, set point input is an analog current signal 4 ... 20 mA, as a tubular valve installation or installed on the common, inlet air manifold (provide air manifold as required). LFR-1/2-D-5M-MAXI-MPA 8002377, LFR-D-MIDID series lockable pressure reducing valve LRS-1/4-D-7-I-MINI, D series lockable pressure reducing valve LRS-1/4-D-7-MIDIDSBC-40-60-PPVA-N3,, DSBC-63-150-D3-PPSA-N3DGC-K-25-800-PPV-A-GK,, 193144 GRLA-1/8-QS-6-D pressure reducing valve LR-M2-N1/4-07K, vacuum suction cup VAS-100-1/4-SIVN-10-L-T3-PQ2-VQ2-RO1, DSBC-32-70-PPVA-N3,DSBC-125-125-PPSA-N3, DFM-12-30-P-A-GF1312501 DGC-K-25-180-PPV-A-GK ZUB 2Y, plastic air tube PUN-H-3X0,5-SW pressure reducing valve LR-M2-N1/2-16IK, LFR-3/4-D-MIDI-A-MPAAEVULQZ-50-20-P-A,, D series lockable pressure reducing valve L

Double-acting cylinder CMK2-00-25-145 belongs to the Air Pressure Cylinders series under CKD company, model number CMK2-00-25-145. To purchase or inquire about Double-acting cylinder CMK2-00-25-145, you can directly contact 158 0047 0089 (Mr. He).

FAQ

  • What is the basic function of CKD pneumatic components?
    CKD pneumatic components use compressed air as a power source to transmit and convert forces. They can be used to control machine movements, transmit force, or achieve automation. Common pneumatic components include cylinders, pneumatic valves, and pneumatic motors.
  • What are the main types of CKD pneumatic components?

    1. Cylinders: Used to convert the energy of compressed air into mechanical energy to produce linear motion.

    2. Pneumatic valves: Used to control the direction, speed, and pressure of airflow, regulating the operation of pneumatic systems.

    3. Pneumatic motors: Devices that convert compressed air into rotary motion.

    4. Air tubes and connectors: Used to connect various components in pneumatic systems and transmit air.

  • Do CKD pneumatic components require regular maintenance? If yes, what are the key points?

    Yes, CKD pneumatic components require regular maintenance to ensure normal operation and extend service life. Key maintenance points include:

    - Regularly check and replace seals and gaskets to prevent air leakage.

    - Inspect and clean filters to ensure clean air quality.

    - Lubricate moving parts to reduce wear and improve efficiency.

    - Check air tubes and connectors to ensure secure and undamaged connections.

  • How to choose the right CKD pneumatic components?

    When selecting the appropriate CKD pneumatic components, consider the following factors:

    Application requirements: Understand the specific working environment and tasks, such as load, speed, and stroke.

    Air source conditions: Ensure that the pressure and flow of the air source meet the component’s requirements.

    Installation space: Confirm available space and choose components of suitable size.

    Environmental factors: Consider the temperature, humidity, and potential corrosiveness of the working environment to select suitable materials and designs.

  • What are common faults in CKD pneumatic component systems and how to troubleshoot?

    Common pneumatic system faults include:

    Air leakage: Causes efficiency decline; check seals, connections, and tubes, find leak points, and repair or replace.

    Stuck cylinder piston: Possibly caused by dirt or insufficient lubrication; clean the piston and add lubricant.

    Valve failure: Check electrical control signals, ensure smooth airflow, and verify if the valve itself is damaged.

    Insufficient pressure: Inspect air source pressure, filters, and piping to ensure no blockage or leakage.

Related Products