Language
Home > CKD > Air Pressure Cylinders
Double acting cylinder CMK2-C-00-20-75

CKD Double acting cylinder CMK2-C-00-20-75

Brand:CKD Model:CMK2-C-00-20-75

CMK2-C-00-20-75 has a small footprint: for producing the same amount of water, the area occupied is less than 1/3 of that of a conventional sand filter. The buffer acts as a variable resistance in the pipeline. It changes the turbulence of the process fluid or provides a pressure drop in laminar flow conditions, which is caused by changing the valve resistance or 'friction'. This pressure reductio ...
CMK2-C-00-20-75 has a small footprint: for producing the same amount of water, the area occupied is less than 1/3 of that of a conventional sand filter. The buffer acts as a variable resistance in the pipeline. It changes the turbulence of the process fluid or provides a pressure drop in laminar flow conditions, which is caused by changing the valve resistance or 'friction'. This pressure reduction process is commonly referred to as 'throttling'. For gases, it approaches an isothermal adiabatic state, with deviations depending on the degree of non-ideality of the gas [Joule-Thomson effect]. In the case of liquids, the pressure is consumed by turbulence or viscous friction, both of which convert pressure into heat energy, resulting in a slight increase in temperature. During the installation of the cylinder, the following points should be noted: After draining, close the drain valve, turn the transfer handle to 'open', and the valve plate will be in the open position again, allowing the filter to operate normally. Due to the small drain port, the water flow rate is relatively small, and the draining time is short, so draining has little impact on the normal operation of the system, and therefore, no centralized draining is required. Pressure reducing valves LR-M2-N3/8-07GI, LF-D-MINI-AAEVULQZ-32-30-P-A-S6, AEVULQZ-25-15-A-P-A double-acting anti-twist cylinder DZH-63-25-PPV-A, DSBC-32-60-D3-PPSA-N3LFR-1/4-D-MIDI-A-MPA, PUN-CM-8-SW pressure reducing valve LR-M2-N1/4-10GI, pressure reducing valve LR-M1-N1/4-07IK vacuum suction cup VAS-15-1/8-PUR-CT, both ends with elastic buffer pad DSM-6-90-PDFM-12-80-P-A-GF, EMME-AS-60-S-LS-ASCLR-63-20-R-P-A, pressure reducing valve LR-M3-G1/2-07IGRLA-1/8-B, vacuum suction cup ESS-10X30-ON vacuum suction cup ESV-50-SNA, LFR-1/2-D-5M-MIDIDFM-63-200-P-A-KF, D series pressure reducing valve LR-3/8-D-7-O-I-MIDID series pressure reducing valve LR-3/8-D-7-O-I-MINI, MPPES-3-1/4-6-420AEVULQ-63-50-A-P-A-S206, DFM-100-100-P-A-KFDSBC-100-40-PPVA-N3, pressure reducing valve LR-M1-G1/4-04IDGC-K-50-200-PPV-A-GK, vacuum suction cup ESV-20-SN basic valve LR-D-7-MINI, DFM-16-40-P-A-KFAEVULQZ-20-15-P-A, pressure reducing valve LR-M2-N1/2-16GIKDSBC-63-80-D3-PPSA-N3, vacuum suction cup ESV-20-SS air tube PUN-12X2-S-6-BL, DGC-K-32-1100-PPV-A-GK pressure regulating valve LRBS

Double acting cylinder CMK2-C-00-20-75 belongs to the Air Pressure Cylinders series under CKD company, model number CMK2-C-00-20-75. To purchase or inquire about Double acting cylinder CMK2-C-00-20-75, you can directly contact 158 0047 0089 (Mr. He).

FAQ

  • What is the basic function of CKD pneumatic components?
    CKD pneumatic components use compressed air as a power source to transmit and convert forces. They can be used to control machine movements, transmit force, or achieve automation. Common pneumatic components include cylinders, pneumatic valves, and pneumatic motors.
  • What are the main types of CKD pneumatic components?

    1. Cylinders: Used to convert the energy of compressed air into mechanical energy to produce linear motion.

    2. Pneumatic valves: Used to control the direction, speed, and pressure of airflow, regulating the operation of pneumatic systems.

    3. Pneumatic motors: Devices that convert compressed air into rotary motion.

    4. Air tubes and connectors: Used to connect various components in pneumatic systems and transmit air.

  • Do CKD pneumatic components require regular maintenance? If yes, what are the key points?

    Yes, CKD pneumatic components require regular maintenance to ensure normal operation and extend service life. Key maintenance points include:

    - Regularly check and replace seals and gaskets to prevent air leakage.

    - Inspect and clean filters to ensure clean air quality.

    - Lubricate moving parts to reduce wear and improve efficiency.

    - Check air tubes and connectors to ensure secure and undamaged connections.

  • How to choose the right CKD pneumatic components?

    When selecting the appropriate CKD pneumatic components, consider the following factors:

    Application requirements: Understand the specific working environment and tasks, such as load, speed, and stroke.

    Air source conditions: Ensure that the pressure and flow of the air source meet the component’s requirements.

    Installation space: Confirm available space and choose components of suitable size.

    Environmental factors: Consider the temperature, humidity, and potential corrosiveness of the working environment to select suitable materials and designs.

  • What are common faults in CKD pneumatic component systems and how to troubleshoot?

    Common pneumatic system faults include:

    Air leakage: Causes efficiency decline; check seals, connections, and tubes, find leak points, and repair or replace.

    Stuck cylinder piston: Possibly caused by dirt or insufficient lubrication; clean the piston and add lubricant.

    Valve failure: Check electrical control signals, ensure smooth airflow, and verify if the valve itself is damaged.

    Insufficient pressure: Inspect air source pressure, filters, and piping to ensure no blockage or leakage.

Related Products