Language
Home > CKD > Air Pressure Cylinders
Double-acting cylinder SSD-KL-50C-10

CKD Double-acting cylinder SSD-KL-50C-10

Brand:CKD Model:SSD-KL-50C-10

The nominal pressure of the SSD-KL-50C-10 solenoid valve should exceed the maximum working pressure inside the pipe. The width of the sealing surface is large. If the sealing pressure is low under the condition of constant spring pressure, and if this pressure is lower than the working pressure of the boiler system, it will cause leakage. The solution is to reprocess the sealing surface to a reaso ...
The nominal pressure of the SSD-KL-50C-10 solenoid valve should exceed the maximum working pressure inside the pipe. The width of the sealing surface is large. If the sealing pressure is low under the condition of constant spring pressure, and if this pressure is lower than the working pressure of the boiler system, it will cause leakage. The solution is to reprocess the sealing surface to a reasonable size and grind it for use. The working principle diagram of the rodless cylinder. The rodless cylinder is a type of hydraulic pump that axially arranges multiple pistons on the circumference of a common cylinder body, with the centerline of the piston and the centerline of the cylinder body being parallel. There are two structural forms of axial piston pumps: straight shaft (swash plate type) and inclined shaft (rocking cylinder type). The advantages of the axial piston pump are: compact structure, small radial dimensions, small inertia, high volumetric efficiency, and the current highest pressure can reach 40MPa or even higher, generally used in high-pressure systems such as construction machinery, presses, etc. However, its axial dimensions are larger, the axial force is also larger, and the structure is relatively complex.D1-29AAC-4JB, M-45001-01PMV-A1C-A121-PM-611JJ, 45A-SE2-DDAA-1BA45A-AA1-DDAB-1CM M0D: R0HS, 916595M-18001-01-01P, 45A-L00-DDAJ-1JB35A-AAA-DDAA-1CA, 35A-B00-DDBA-1BAPME-502JM, 34C-ABA-GDFA-1BADMB-DJDJ-1KJ1, 411A-D0A-DM-DDAJ-1JM35A-AAA-DDAA-1CM, 6642A-331-PM-501JJPPC5C-AAA-BGAA-BBB-F0 M0D: 1207, PPC5C-AAA-AGAA-BBB-F0 M0D:EA5424A-AA-000-EM2-RDCP-1FA, 35A-AAA-DEDA-1BA M0D:1172711C-12-PI-611CA, PPC5C-AAA-AGAA-BBB-F0 M0D:120752A-11-D0B-DM-DJBA-1BA, 130B-501JJE-34002-018, 116B-501JM M0D:038934C-L00-GDD0-2DJ, 56C-16-611JCA2-7009, BV310A-CC1-00-BHEA-CTA45A-AA1-DDAA-1BA M0D:T65C, 6311D-312-PM-502DA916B-PM-501JM, 6321D-313-PM

Double-acting cylinder SSD-KL-50C-10 belongs to the Air Pressure Cylinders series under CKD company, model number SSD-KL-50C-10. To purchase or inquire about Double-acting cylinder SSD-KL-50C-10, you can directly contact 158 0047 0089 (Mr. He).

FAQ

  • What is the basic function of CKD pneumatic components?
    CKD pneumatic components use compressed air as a power source to transmit and convert forces. They can be used to control machine movements, transmit force, or achieve automation. Common pneumatic components include cylinders, pneumatic valves, and pneumatic motors.
  • What are the main types of CKD pneumatic components?

    1. Cylinders: Used to convert the energy of compressed air into mechanical energy to produce linear motion.

    2. Pneumatic valves: Used to control the direction, speed, and pressure of airflow, regulating the operation of pneumatic systems.

    3. Pneumatic motors: Devices that convert compressed air into rotary motion.

    4. Air tubes and connectors: Used to connect various components in pneumatic systems and transmit air.

  • Do CKD pneumatic components require regular maintenance? If yes, what are the key points?

    Yes, CKD pneumatic components require regular maintenance to ensure normal operation and extend service life. Key maintenance points include:

    - Regularly check and replace seals and gaskets to prevent air leakage.

    - Inspect and clean filters to ensure clean air quality.

    - Lubricate moving parts to reduce wear and improve efficiency.

    - Check air tubes and connectors to ensure secure and undamaged connections.

  • How to choose the right CKD pneumatic components?

    When selecting the appropriate CKD pneumatic components, consider the following factors:

    Application requirements: Understand the specific working environment and tasks, such as load, speed, and stroke.

    Air source conditions: Ensure that the pressure and flow of the air source meet the component’s requirements.

    Installation space: Confirm available space and choose components of suitable size.

    Environmental factors: Consider the temperature, humidity, and potential corrosiveness of the working environment to select suitable materials and designs.

  • What are common faults in CKD pneumatic component systems and how to troubleshoot?

    Common pneumatic system faults include:

    Air leakage: Causes efficiency decline; check seals, connections, and tubes, find leak points, and repair or replace.

    Stuck cylinder piston: Possibly caused by dirt or insufficient lubrication; clean the piston and add lubricant.

    Valve failure: Check electrical control signals, ensure smooth airflow, and verify if the valve itself is damaged.

    Insufficient pressure: Inspect air source pressure, filters, and piping to ensure no blockage or leakage.