CKD Dryer HD-1-AC100V rotary switch settings should be performed using a precision screwdriver, etc. If too much force is applied to the rotating part, there is a possibility of poor contact with the contacts, please pay full attention. The set value of the flow rate is fixed, as shown in the table on the right. If you need to change the value, please discuss separately. The function description divides the alarm output flow rate into 10 levels. Divides the alarm output flow rate into 10 levels. OUT 1: Wire (Black) OUT 2: Wire (Orange) Corresponding. Displays the state of the alarm output. Displays the state of the alarm output. Displays the instantaneous flow rate. Displayed as a decimal for flows below 10 /min and as an integer for flows above 10 /min. Water within the discharge specification range, light on. Power on light on. When wiring, please be sure to refer to the precautions for use. The connector uses the VA connector produced by Corens Company (Model: TM-4DSX3HG4) Specifications: DC use, 4-core 0.5mm 2 Selection items (analog output, alarm output form) No signature; (0-5 [V], NPN-P; (0-5 [V], PNP) -A1; (4-20 [mA]) -A2; (1-5 [V], NPN-PA2; (1-5 [V], PNP) -A3; (0-10 [V], NPN) -PA3; (0-10 [V], PNP) -A4; (No analog output, NPN-PA4 (No analog output, PNP) -A5; (Alarm 2-point output, NPN) Connect the positive pole of the DC power supply: DC 12~24V±10% Analog output: Output voltage proportional to the flow Analog output (NPN): MAX.DC30V 50mA Connect the negative pole of the DC power supply: DC 0V Output indicator light However, OUT2 only selects options. Cumulative flow maximum 9 digits
Dryer HD-1-AC100V belongs to the Controllers series under CKD company, model number HD-1-AC100V. To purchase or inquire about Dryer HD-1-AC100V, you can directly contact 158 0047 0089 (Mr. He).
1. Cylinders: Used to convert the energy of compressed air into mechanical energy to produce linear motion.
2. Pneumatic valves: Used to control the direction, speed, and pressure of airflow, regulating the operation of pneumatic systems.
3. Pneumatic motors: Devices that convert compressed air into rotary motion.
4. Air tubes and connectors: Used to connect various components in pneumatic systems and transmit air.
Yes, CKD pneumatic components require regular maintenance to ensure normal operation and extend service life. Key maintenance points include:
- Regularly check and replace seals and gaskets to prevent air leakage.
- Inspect and clean filters to ensure clean air quality.
- Lubricate moving parts to reduce wear and improve efficiency.
- Check air tubes and connectors to ensure secure and undamaged connections.
When selecting the appropriate CKD pneumatic components, consider the following factors:
Application requirements: Understand the specific working environment and tasks, such as load, speed, and stroke.
Air source conditions: Ensure that the pressure and flow of the air source meet the component’s requirements.
Installation space: Confirm available space and choose components of suitable size.
Environmental factors: Consider the temperature, humidity, and potential corrosiveness of the working environment to select suitable materials and designs.
Common pneumatic system faults include:
Air leakage: Causes efficiency decline; check seals, connections, and tubes, find leak points, and repair or replace.
Stuck cylinder piston: Possibly caused by dirt or insufficient lubrication; clean the piston and add lubricant.
Valve failure: Check electrical control signals, ensure smooth airflow, and verify if the valve itself is damaged.
Insufficient pressure: Inspect air source pressure, filters, and piping to ensure no blockage or leakage.