festoGuide cylinderDFM-63-200-P-A-KFThe condensate water discharge device is made of an optical measurement and control system with different principles of action of light flux on photoelectric elements, which are diverse. According to the nature of the output quantity of the photoelectric elements (optical measurement and control system), they can be divided into two categories, namely analog photoelectric sensors and pulse (switch) photoelectric sensors. The analog photoelectric sensor converts the measured quantity into a continuously varying photoelectric current, which has a single-value relationship with the measured quantity. The robust design, precise pressure measurement technology. The blank plate is used to seal the prefabricated cable socket with a cable socket, LED, and protection circuit for user-installed cables and electromagnets manual control device, semi-tubular valve, threaded connection single installation base mounting valve freight date check, controller function output pressure constant with second exhaust channel, pneumatic connection, air port 1G1/4 pneumatic connection, air port QS-6, installation type with through hole standard rated flow 96 l/min, input pressure 0 ... 9 bar ambient temperature 0 ... 60 °C material information, housing PBT-reinforced, operating medium compressed air in accordance with, drive lock with locking nut assembly position arbitrary, design structure direct control piston regulator with loop air source system, pressure gauge with pressure gauge pressure control range 1 ... 8 bar, product weight 55 g material information, threaded plug brass, nickel-plated material information, threaded seal PTFE, base series base valve, top tube connection, PRS airway board MEBH single electric control, with EB type solenoid coil, MOEBH single electric control, with EB type solenoid coil, normally open MEH single electric control, with E type solenoid coil, MOEH single electric control, with E type solenoid coil, normally open JMEBH double electric control, with EB type solenoid coil, JMEH double electric control, with E type solenoid coil, valve function 3/2 two-position three-way valve 5/2 two-position five-way valve 5/3 three-position five-way valve, original position G closed type E venting type B medium pressure type, structural features, air interface/nominal diameter, semi-tubular valve, thread 5.0 base-mounted valve, chemical-resistant joint cause and repair method of joint damage; joint maintenance and inspection, differences in which aspects are reflected; the joint adjusts the outlet pressure by adjusting the spring pressure, utilizes the diaphragm to sense the change of the outlet pressure, and through the gas pressure reducing valve, the main valve is driven by the pilot valve to open and close, adjusting the throttle area of the main valve to achieve the pressure reducing and stabilizing function. The gas pressure reducing valve consists of two parts, the main valve and the pilot valve. The main valve mainly consists of valve seat, main valve disc, piston, cylinder liner, spring, and other parts. The pilot valve mainly consists of valve seat, valve flap, diaphragm, spring, adjusting spring, and other parts. Gas pressure reducing valve products are mainly used for gas pipelines, such as air, nitrogen, oxygen, hydrogen, liquefied gas, natural gas, and other gases.festoGuide cylinderDFM-63-200-P-A-KFusing a flexible coupling to ensure that the radial load is below the allowable value, this is specially designed for servo motors with high mechanical strength. After the cylinder cross pin is installed, it must be in the cross pin
Guided Cylinder DFM-63-200-P-A-KF belongs to the Air Pressure Cylinders series under CKD company, model number DFM-63-200-P-A-KF. To purchase or inquire about Guided Cylinder DFM-63-200-P-A-KF, you can directly contact 158 0047 0089 (Mr. He).
1. Cylinders: Used to convert the energy of compressed air into mechanical energy to produce linear motion.
2. Pneumatic valves: Used to control the direction, speed, and pressure of airflow, regulating the operation of pneumatic systems.
3. Pneumatic motors: Devices that convert compressed air into rotary motion.
4. Air tubes and connectors: Used to connect various components in pneumatic systems and transmit air.
Yes, CKD pneumatic components require regular maintenance to ensure normal operation and extend service life. Key maintenance points include:
- Regularly check and replace seals and gaskets to prevent air leakage.
- Inspect and clean filters to ensure clean air quality.
- Lubricate moving parts to reduce wear and improve efficiency.
- Check air tubes and connectors to ensure secure and undamaged connections.
When selecting the appropriate CKD pneumatic components, consider the following factors:
Application requirements: Understand the specific working environment and tasks, such as load, speed, and stroke.
Air source conditions: Ensure that the pressure and flow of the air source meet the component’s requirements.
Installation space: Confirm available space and choose components of suitable size.
Environmental factors: Consider the temperature, humidity, and potential corrosiveness of the working environment to select suitable materials and designs.
Common pneumatic system faults include:
Air leakage: Causes efficiency decline; check seals, connections, and tubes, find leak points, and repair or replace.
Stuck cylinder piston: Possibly caused by dirt or insufficient lubrication; clean the piston and add lubricant.
Valve failure: Check electrical control signals, ensure smooth airflow, and verify if the valve itself is damaged.
Insufficient pressure: Inspect air source pressure, filters, and piping to ensure no blockage or leakage.