SCA2-CB-50B-75-I Let me give a brief introduction. In terms of air (or hydraulic) lines, a two-position three-way solenoid valve has one air inlet (connected to the air source), one air outlet (providing air to the target device), and one exhaust port (usually equipped with a silencer, if不怕噪音的话也可以不装@_@). A two-position five-way solenoid valve has one air inlet (connected to the air source), one po ...
SCA2-CB-50B-75-I Let me give a brief introduction. In terms of air (or hydraulic) lines, a two-position three-way solenoid valve has one air inlet (connected to the air source), one air outlet (providing air to the target device), and one exhaust port (usually equipped with a silencer, if不怕噪音的话也可以不装@_@). A two-position five-way solenoid valve has one air inlet (connected to the air source), one positive action air outlet and one reverse action air outlet (providing air sources for the positive and reverse actions of the target device respectively), one positive action exhaust port and one reverse action exhaust port (equipped with silencers). For small automatic control equipment, air pipes generally choose 8~12mm industrial rubber air pipes. Solenoid valves generally choose (a bit upscale, but small products), Taiwan Airtac (cost-effective, quality is also good) or other domestic brands, etc. MDC2-L-6-4-F2H-D, SCA2-FA-40N-125/ZHCM-LB-40B-600, SCS2-FB-125B-150-G/ZSC-M5-S, SCA2-LB-63B-40-T0H-D/ZCHB-V1-32-ED2-S-DC24V, M3PA210-06-C20-9-3/ZVSP-C4RSE-4, WFK7100-25-A53PB210-08-3/Z, 4JA339-08-E2-3/ZSRL3-00-50B-360/T, LGD11-4SEVD-3500-208AN-3/Z, MXB1-15-H-2B2019-2C-PGB, CHB-15/Z4KB130-06-M1C-DC24V, 4F140-08-M1E-DC24VP5142-M6C2-DC24V, SCA2-CB-50B-30/ZSCL2-06-H66, SCA2-CA-50B-90-I/ZWFK5027-20-B, AX4150TH-DM04-U0/ZWFK5008-20, AX4075TS-DM04-U0/ZEMB41-10-3-AC110V, ETS-10-16070-EP1NCBNPSLW-8A-H, SRL3-00-16B-1000-R/T4KB119-00-AC220V, FBU2-7DHV-02-6-TBH3QEV2-10/T, AB41E4-03-3-D3T-DC24VSW-R2Y, FGB51-10-5-13RS-3SW-M2WV, RVU300-90-M0V-DSU-3050-A07-W, MDC2-8-8SSG-L-12-20, NCK-00-2.6-CUSB2-M5-2-DC24V/T, FCD-DL-32-104GB229R-00-A2N-3, PDV3-20A-2H-DC24V/Z4GB259R-00-A2

Medium Cylinder SCA2-CB-50B-75-I belongs to the Air Pressure Cylinders series under CKD company, model number SCA2-CB-50B-75-I. To purchase or inquire about Medium Cylinder SCA2-CB-50B-75-I, you can directly contact 158 0047 0089 (Mr. He).

FAQ

  • What is the basic function of CKD pneumatic components?
    CKD pneumatic components use compressed air as a power source to transmit and convert forces. They can be used to control machine movements, transmit force, or achieve automation. Common pneumatic components include cylinders, pneumatic valves, and pneumatic motors.
  • What are the main types of CKD pneumatic components?

    1. Cylinders: Used to convert the energy of compressed air into mechanical energy to produce linear motion.

    2. Pneumatic valves: Used to control the direction, speed, and pressure of airflow, regulating the operation of pneumatic systems.

    3. Pneumatic motors: Devices that convert compressed air into rotary motion.

    4. Air tubes and connectors: Used to connect various components in pneumatic systems and transmit air.

  • Do CKD pneumatic components require regular maintenance? If yes, what are the key points?

    Yes, CKD pneumatic components require regular maintenance to ensure normal operation and extend service life. Key maintenance points include:

    - Regularly check and replace seals and gaskets to prevent air leakage.

    - Inspect and clean filters to ensure clean air quality.

    - Lubricate moving parts to reduce wear and improve efficiency.

    - Check air tubes and connectors to ensure secure and undamaged connections.

  • How to choose the right CKD pneumatic components?

    When selecting the appropriate CKD pneumatic components, consider the following factors:

    Application requirements: Understand the specific working environment and tasks, such as load, speed, and stroke.

    Air source conditions: Ensure that the pressure and flow of the air source meet the component’s requirements.

    Installation space: Confirm available space and choose components of suitable size.

    Environmental factors: Consider the temperature, humidity, and potential corrosiveness of the working environment to select suitable materials and designs.

  • What are common faults in CKD pneumatic component systems and how to troubleshoot?

    Common pneumatic system faults include:

    Air leakage: Causes efficiency decline; check seals, connections, and tubes, find leak points, and repair or replace.

    Stuck cylinder piston: Possibly caused by dirt or insufficient lubrication; clean the piston and add lubricant.

    Valve failure: Check electrical control signals, ensure smooth airflow, and verify if the valve itself is damaged.

    Insufficient pressure: Inspect air source pressure, filters, and piping to ensure no blockage or leakage.