SCA2-T-TC-80B-50-Y When designing the system, the user chose the pressure tapping point inappropriately (selected at a place where the pressure changes very rapidly), and there were issues with the PID parameter settings of the pressure control module in the control system. This caused the entire system to be overly sensitive, so that even a slight change in pressure would trigger the controller to output a control signal to drive the regulating valve. This resulted in the regulating valve operating frequently, causing oscillation, which in turn caused the entire system to oscillate. Not only could the controlled variable not be stabilized, but the regulating valve was also overburdened and unable to complete the regulation task. BV214A-DA1-00-BBB0-CTA M0D:XQW1, VSP-C10BN-64F310-10-AC220V/Z, N3E066S0-C4-E-3FSL100-44-B, N4E020-C4-E-3FCD-25-22, N4E010-C4-E-3M4F310E-08-2-CU-SUB-BASE-KIT/Z, 3PA210-06-D2P-35477571-REV-C, 4F520-15-L-DC24V/Z27A-11-D0B-DM-DDAJ-1KJ, 4F510-15-L-DC24V/Z23131-61D, 4F750-20-L-DC24V/Z45A-SC1-DDFJ-1KJ M0D:CLSF, AG41E4-02-2-03TA-DC24V34C-ABA-GDFA-1KT, SCA2-TC-63B-200-Y/ZVSB-E12-66, SCA2-FC-40B-300/ZSCS2-N-FA-200B-350-J-G/Z, 4F110-08-DC24V/ZSCS2-00-125B-200-I/Z, STL-BQ-20-250-HM-45008-01P, VSB-H12-66811C-PM-871BA-152, MSTG-M-12-100/KKDU3A-DDAP-1DM M0D:532B, DVL-S-06-H44-020225B-610EE 005EF ECG, SKL-120857D-A6-111JA, A1338-6CAB31-02-5F-2G-DC24V/Z, STS-M-16-30/ZSCS2-N-FA-180B-400/Z, SCS2-FA-180B-400-J-G/ZADK11-25A-03A-DC24V/Z, 4F620-20-L-DC24V/ZPV06B-A0A-46L-DDAJ-1JM M0D:PVVT, CVSE3-20A-70-B3RSB-Z-3 All the above information is provided by Shanghai Ju Guo Pneumatic Equipment Co., Ltd., and unauthorized use is prohibited. For more information, please contact the following customer service.
Medium-sized cylinder SCA2-T-TC-80B-50-Y belongs to the Air Pressure Cylinders series under CKD company, model number SCA2-T-TC-80B-50-Y. To purchase or inquire about Medium-sized cylinder SCA2-T-TC-80B-50-Y, you can directly contact 158 0047 0089 (Mr. He).
1. Cylinders: Used to convert the energy of compressed air into mechanical energy to produce linear motion.
2. Pneumatic valves: Used to control the direction, speed, and pressure of airflow, regulating the operation of pneumatic systems.
3. Pneumatic motors: Devices that convert compressed air into rotary motion.
4. Air tubes and connectors: Used to connect various components in pneumatic systems and transmit air.
Yes, CKD pneumatic components require regular maintenance to ensure normal operation and extend service life. Key maintenance points include:
- Regularly check and replace seals and gaskets to prevent air leakage.
- Inspect and clean filters to ensure clean air quality.
- Lubricate moving parts to reduce wear and improve efficiency.
- Check air tubes and connectors to ensure secure and undamaged connections.
When selecting the appropriate CKD pneumatic components, consider the following factors:
Application requirements: Understand the specific working environment and tasks, such as load, speed, and stroke.
Air source conditions: Ensure that the pressure and flow of the air source meet the component’s requirements.
Installation space: Confirm available space and choose components of suitable size.
Environmental factors: Consider the temperature, humidity, and potential corrosiveness of the working environment to select suitable materials and designs.
Common pneumatic system faults include:
Air leakage: Causes efficiency decline; check seals, connections, and tubes, find leak points, and repair or replace.
Stuck cylinder piston: Possibly caused by dirt or insufficient lubrication; clean the piston and add lubricant.
Valve failure: Check electrical control signals, ensure smooth airflow, and verify if the valve itself is damaged.
Insufficient pressure: Inspect air source pressure, filters, and piping to ensure no blockage or leakage.