Language
Home > CKD > Air Pressure Cylinders
New Cylinder SCS2-CA-125B-200

CKD New Cylinder SCS2-CA-125B-200

Brand:CKD Model:SCS2-CA-125B-200

SCS2-CA-125B-200 Additionally, the throttle and actuation parts of the proportional valve should be designed to avoid setting very small diameter orifices, to prevent clogging. If necessary, a filter should be added, and regular maintenance and the installation of bypass piping should be carried out. The development and application prospects of this type of valve are promising. The daily maintenan ...

SCS2-CA-125B-200 Additionally, the throttle and actuation parts of the proportional valve should be designed to avoid setting very small diameter orifices, to prevent clogging. If necessary, a filter should be added, and regular maintenance and the installation of bypass piping should be carried out. The development and application prospects of this type of valve are promising. The daily maintenance of the electric cylinder involves regularly checking the pressure gauge on the pressure reducing valve to see if the pressure fluctuates with the air compressor. If the air pressure fluctuates with the air compressor, it indicates that the pressure reducing valve has failed. You can try adjusting the adjustment knob of the pressure reducing valve; if it does not work, you should consider replacing the pressure reducing valve. Unstable air pressure can affect the service life of high-speed handpieces. In addition, it is necessary to regularly drain water from the electric cylinder. More advanced pressure reducing valves can automatically drain water; when the air pressure drops to a certain value, the drain valve will automatically open. Some older electric cylinders require people to regularly open the drain valve at the bottom to drain water. SCL2-10-H88, PPG-D-RNC-6BM1/KT4RD219-06-E2-3/Z, PPG-D-KHSCB/KTM4JA2-6/Z, PPX-R10N-6M-KA/PSRL3-00-16B-300-M0H3-D-A/T, SCA2-Q2-FA-63B-100-H-T0H3-D/ZPRA2D-5AAA, SCA2-Q2-FA-40B-75-H-T0H3-D/Z34B-AAA M0D:7108, SCA2-00-40B-25/ZBV210A-DA1-00-BEGA-CBA, SCA2-FA-80B-200-Y/Z35A-ACA-DDAJ-1KA, CMA2-TA-30-100434A-D0B-DM-DDAJ-1KJ, SRL3-00-25B-740/T4F330E-08-TP-H-X-DC24V, SRG3-LB-20B-350-A2AG41-02-1-02HAB-DC24V, ZJ-S0604-6STS-B-25-10, ZJ-S0604-8811C-PM-501BA-155, ZJ-T0604-045A-AA1-DDAB-1CM M0D: R0HS, FJ-0-186632A-000-PM-113JD, FJ-0-1445A-BC1-DDAA-1BA, M4F310E-08-7-CU-SUB-BASE-KIT93A-ABA-000-DM-DDAF-1BA, 4F310E-10-TP-AC100V/ZAP11-20A-C4A-AC220V/Z, DSG-15-AC100VSCA2-FA-100B-250/Z, AX4075TS-DM04-P3-U0/ZB2019-2C-PGB, 3PB210-06-3/Z45A-LCD-DDAJ-1KD, EVR-2500-08-S16332D-641-RA, CE300-15-F/KK and so on.

New Cylinder SCS2-CA-125B-200 belongs to the Air Pressure Cylinders series under CKD company, model number SCS2-CA-125B-200. To purchase or inquire about New Cylinder SCS2-CA-125B-200, you can directly contact 158 0047 0089 (Mr. He).

FAQ

  • What is the basic function of CKD pneumatic components?
    CKD pneumatic components use compressed air as a power source to transmit and convert forces. They can be used to control machine movements, transmit force, or achieve automation. Common pneumatic components include cylinders, pneumatic valves, and pneumatic motors.
  • What are the main types of CKD pneumatic components?

    1. Cylinders: Used to convert the energy of compressed air into mechanical energy to produce linear motion.

    2. Pneumatic valves: Used to control the direction, speed, and pressure of airflow, regulating the operation of pneumatic systems.

    3. Pneumatic motors: Devices that convert compressed air into rotary motion.

    4. Air tubes and connectors: Used to connect various components in pneumatic systems and transmit air.

  • Do CKD pneumatic components require regular maintenance? If yes, what are the key points?

    Yes, CKD pneumatic components require regular maintenance to ensure normal operation and extend service life. Key maintenance points include:

    - Regularly check and replace seals and gaskets to prevent air leakage.

    - Inspect and clean filters to ensure clean air quality.

    - Lubricate moving parts to reduce wear and improve efficiency.

    - Check air tubes and connectors to ensure secure and undamaged connections.

  • How to choose the right CKD pneumatic components?

    When selecting the appropriate CKD pneumatic components, consider the following factors:

    Application requirements: Understand the specific working environment and tasks, such as load, speed, and stroke.

    Air source conditions: Ensure that the pressure and flow of the air source meet the component’s requirements.

    Installation space: Confirm available space and choose components of suitable size.

    Environmental factors: Consider the temperature, humidity, and potential corrosiveness of the working environment to select suitable materials and designs.

  • What are common faults in CKD pneumatic component systems and how to troubleshoot?

    Common pneumatic system faults include:

    Air leakage: Causes efficiency decline; check seals, connections, and tubes, find leak points, and repair or replace.

    Stuck cylinder piston: Possibly caused by dirt or insufficient lubrication; clean the piston and add lubricant.

    Valve failure: Check electrical control signals, ensure smooth airflow, and verify if the valve itself is damaged.

    Insufficient pressure: Inspect air source pressure, filters, and piping to ensure no blockage or leakage.