Language
Home > CKD > Air Pressure Cylinders
Guided Cylinder DFM-100-125-P-A-KF

CKD Guided Cylinder DFM-100-125-P-A-KF

Brand:CKD Model:DFM-100-125-P-A-KF

festoGuide cylinderDFM-100-125-P-A-KFDue to the cover of the lever arm, only half of the cross pin section can be seen. The design concept can be understood as when the pin becomes loose for various reasons and attempts to move to one side, it will stop after moving a very small displacement by hitting the lever arm. During major repairs, the cross pin hole was reprocessed and moved down by 20mm o ...

festoGuide cylinderDFM-100-125-P-A-KFDue to the cover of the lever arm, only half of the cross pin section can be seen. The design concept can be understood as when the pin becomes loose for various reasons and attempts to move to one side, it will stop after moving a very small displacement by hitting the lever arm. During major repairs, the cross pin hole was reprocessed and moved down by 20mm overall, causing the cross pin to exactly escape the protection of the lever arm, allowing it to smoothly come out during operation and cause the valve rod to move down and close the valve. The structural principle of the servo motor is explained; the valve flap of the servo motor opens under the action of fluid pressure, and the fluid flows from the inlet side to the outlet side. When the pressure on the inlet side is lower than that on the outlet side, the valve flap automatically closes under the action of fluid pressure difference, its own gravity, and other factors to prevent fluid from reversing. Check valves are generally divided into lift, swing, butterfly, and diaphragm types. 3. Selection of mesh count: mainly consider the size of the impurity particles to be intercepted, determined according to the process requirements of the medium flow. Various specifications of wire mesh can intercept the particle size dimensions, check the table 'Filter Mesh Specifications'. The positioning of the cylinder for pressure testing is actually achieved through a measurement system. From the perspective of actual operation, the above is to achieve accurate measurement, it is necessary to properly position the system. The piston movement speed of the German cylinder is closely related to the air source pressure, load, inlet and outlet pipe joint diameter, etc. Among them, the exhaust speed has the greatest influence. If high-speed movement of the piston rod is required, larger diameter inlet and exhaust ports and conduits should be selected. Usually, to achieve a slow and stable piston rod movement speed, a cylinder with a throttle device or a gas-liquid damping device can be selected. Throttle speed control methods include: when a horizontally installed cylinder is used to push a load, exhaust throttling is recommended; if a vertically installed cylinder is used to lift a heavy object, a rodless cylinder with a buffer device should be selected. 2. A supercharger should generally be installed vertically, and in special cases, it can be inclined, such as when the inclination angle is very large or the valve itself is too heavy, additional support components should be added to protect the valve. Second, ensure that the flow required for the application is met. A good micro-seal ring needs to optimize the use of electrical energy and also reduce the weight of the valve body, making full use of every ampere of electrical energy generated by the battery or power supply. There are six subcategories of solenoid valves based on differences in valve structure and materials and differences in principle: direct-acting diaphragm structure, step-by-step direct-acting diaphragm structure, pilot diaphragm structure, direct-acting piston structure, step-by-step direct-acting piston structure, pilot piston structure.festoGuide cylinderDFM-100-125-P-A-KF can have AI feedback signals, can be controlled by DO or AO, and is commonly found in large pipes and air valves, etc. [1] 1. Switching form: The swing cylinder is driven by a coil and can only be opened or closed, with a short action time when switching. The driving of the swing cylinder is usually by a motor, and the opening or closing action requires a certain amount of time for adjustment. The corrosion resistance of the buffer should also be considered. Since the buffer is in direct contact with the medium, it may be corroded or abraded by temperature, pressure, viscosity, or media containing solid particles and corrosive media, and the corrosion or abrasion forms are diverse. The valve core and valve seat are subject to high-speed scouring by the medium,

Guided Cylinder DFM-100-125-P-A-KF belongs to the Air Pressure Cylinders series under CKD company, model number DFM-100-125-P-A-KF. To purchase or inquire about Guided Cylinder DFM-100-125-P-A-KF, you can directly contact 158 0047 0089 (Mr. He).

FAQ

  • What is the basic function of CKD pneumatic components?
    CKD pneumatic components use compressed air as a power source to transmit and convert forces. They can be used to control machine movements, transmit force, or achieve automation. Common pneumatic components include cylinders, pneumatic valves, and pneumatic motors.
  • What are the main types of CKD pneumatic components?

    1. Cylinders: Used to convert the energy of compressed air into mechanical energy to produce linear motion.

    2. Pneumatic valves: Used to control the direction, speed, and pressure of airflow, regulating the operation of pneumatic systems.

    3. Pneumatic motors: Devices that convert compressed air into rotary motion.

    4. Air tubes and connectors: Used to connect various components in pneumatic systems and transmit air.

  • Do CKD pneumatic components require regular maintenance? If yes, what are the key points?

    Yes, CKD pneumatic components require regular maintenance to ensure normal operation and extend service life. Key maintenance points include:

    - Regularly check and replace seals and gaskets to prevent air leakage.

    - Inspect and clean filters to ensure clean air quality.

    - Lubricate moving parts to reduce wear and improve efficiency.

    - Check air tubes and connectors to ensure secure and undamaged connections.

  • How to choose the right CKD pneumatic components?

    When selecting the appropriate CKD pneumatic components, consider the following factors:

    Application requirements: Understand the specific working environment and tasks, such as load, speed, and stroke.

    Air source conditions: Ensure that the pressure and flow of the air source meet the component’s requirements.

    Installation space: Confirm available space and choose components of suitable size.

    Environmental factors: Consider the temperature, humidity, and potential corrosiveness of the working environment to select suitable materials and designs.

  • What are common faults in CKD pneumatic component systems and how to troubleshoot?

    Common pneumatic system faults include:

    Air leakage: Causes efficiency decline; check seals, connections, and tubes, find leak points, and repair or replace.

    Stuck cylinder piston: Possibly caused by dirt or insufficient lubrication; clean the piston and add lubricant.

    Valve failure: Check electrical control signals, ensure smooth airflow, and verify if the valve itself is damaged.

    Insufficient pressure: Inspect air source pressure, filters, and piping to ensure no blockage or leakage.