Understand the selection principle of the festo standard cylinder DFM-40-25-P-A-KF; smooth anodized piston rod S6 with high temperature resistant seals, up to 120°C S10 slow (constant speed motion) S11 low friction R3 high corrosion resistance grade R8 dustproof TL additional nameplate TT low temperature resistance, pay attention to the working range of the proximity switch 2) Corrosion resistance ...
Understand the selection principle of the festo standard cylinder DFM-40-25-P-A-KF; smooth anodized piston rod S6 with high temperature resistant seals, up to 120°C S10 slow (constant speed motion) S11 low friction R3 high corrosion resistance grade R8 dustproof TL additional nameplate TT low temperature resistance, pay attention to the working range of the proximity switch 2) Corrosion resistance grade 2, in accordance with FN940070 standard moderate corrosion resistance. Applications where condensation water may occur. Used for external visible parts with surface decoration requirements, in direct contact with the environmental climate of typical industrial applications. Corrosion resistance grade 3, in accordance with FN940070 standard high corrosion resistance. Outdoor exposure to moderate corrosive conditions. Used for external visible parts with main functional requirements, in direct contact with conventional industrial environments. This parameter represents the maximum achievable value. Must comply with the maximum allowable impact energy. The torque on the piston rod does not include a greater extension distance than shown in the diagram. If a=0, the corresponding basic type ADN lateral load line is available (page 15). Anodized aluminum N100/125 coated anodized aluminum 2 cylinder barrel anodized aluminum 3 piston rod high alloy steel annealed steel, hard chrome plated high alloy steel anodized aluminum 4 flange screws N12...16 high alloy steel high alloy steel 4. Before installing the supercharger, the pipeline should be cleaned to remove dirt and slag. After installation, the valve should be cleaned again to ensure that no impurities remain in the valve body, that is, when the medium is passed through, all valves should be opened to prevent impurities from jamming. After using the hand wheel mechanism, it should be restored to the original neutral position. 2. Rockwell hardness tester: mainly tests the hardness of the piston rod material, the types of hardness include Brinell hardness and Rockwell hardness, here the Rockwell hardness is generally tested in the piston rod. Control requirements: spray high-pressure water into the steam to make the steam temperature reach the control requirements, working conditions: water, large pressure difference, 2. Applied in safety control systems; pressure magnetic switches are often used in safety control systems, mainly for the safety management system of the air compressor itself. There are many magnetic switch applications in the safety control field, and the pressure magnetic switch, as a very common magnetic switch, is not surprising in the safety control system. In the safety control field, performance is usually considered, price is considered, and practical operation safety and convenience are considered. It has been proven that choosing a pressure magnetic switch is very effective. The pressure magnetic switch utilizes mechanical processing technology to install some components and signal regulators on a very small chip. Therefore, small size is one of its advantages, in addition, cheap price is another big advantage. To some extent, it can improve the accuracy of system testing. In the safety control system, by installing a pressure magnetic switch in the pipeline equipment at the outlet, it can control the pressure brought by the compressor to some extent, which is a certain protective measure and is also a very effective control system. When the compressor starts normally, if the pressure value does not reach the upper limit, then the controller

Guided Cylinder DFM-40-25-P-A-KF belongs to the Air Pressure Cylinders series under CKD company, model number DFM-40-25-P-A-KF. To purchase or inquire about Guided Cylinder DFM-40-25-P-A-KF, you can directly contact 158 0047 0089 (Mr. He).

FAQ

  • What is the basic function of CKD pneumatic components?
    CKD pneumatic components use compressed air as a power source to transmit and convert forces. They can be used to control machine movements, transmit force, or achieve automation. Common pneumatic components include cylinders, pneumatic valves, and pneumatic motors.
  • What are the main types of CKD pneumatic components?

    1. Cylinders: Used to convert the energy of compressed air into mechanical energy to produce linear motion.

    2. Pneumatic valves: Used to control the direction, speed, and pressure of airflow, regulating the operation of pneumatic systems.

    3. Pneumatic motors: Devices that convert compressed air into rotary motion.

    4. Air tubes and connectors: Used to connect various components in pneumatic systems and transmit air.

  • Do CKD pneumatic components require regular maintenance? If yes, what are the key points?

    Yes, CKD pneumatic components require regular maintenance to ensure normal operation and extend service life. Key maintenance points include:

    - Regularly check and replace seals and gaskets to prevent air leakage.

    - Inspect and clean filters to ensure clean air quality.

    - Lubricate moving parts to reduce wear and improve efficiency.

    - Check air tubes and connectors to ensure secure and undamaged connections.

  • How to choose the right CKD pneumatic components?

    When selecting the appropriate CKD pneumatic components, consider the following factors:

    Application requirements: Understand the specific working environment and tasks, such as load, speed, and stroke.

    Air source conditions: Ensure that the pressure and flow of the air source meet the component’s requirements.

    Installation space: Confirm available space and choose components of suitable size.

    Environmental factors: Consider the temperature, humidity, and potential corrosiveness of the working environment to select suitable materials and designs.

  • What are common faults in CKD pneumatic component systems and how to troubleshoot?

    Common pneumatic system faults include:

    Air leakage: Causes efficiency decline; check seals, connections, and tubes, find leak points, and repair or replace.

    Stuck cylinder piston: Possibly caused by dirt or insufficient lubrication; clean the piston and add lubricant.

    Valve failure: Check electrical control signals, ensure smooth airflow, and verify if the valve itself is damaged.

    Insufficient pressure: Inspect air source pressure, filters, and piping to ensure no blockage or leakage.