The sliding parts of the Festo gripper DHWS-32-A-NC cylinder barrel and piston rod must not be damaged to prevent poor cylinder action and damage to the piston rod seal, causing air leakage. The buffer valve should have appropriate maintenance and adjustment space, and magnetic switches should have appropriate installation and adjustment space. If the agent is left unused for a long time, it should be operated once a month and oiled for protection against rust. When the cylinder is used in frequent work and high vibration situations, anti-loosening measures should be taken for the installation screws and all connecting parts. If the agent works in a high-temperature environment for a long time, and the cylinder and piston slide under poor lubrication conditions, there is direct contact between small parts of the metal, friction generates a large amount of heat causing local high temperature, which leads to metal melting, tearing, and gradual expansion causing wear. If the oil film can be restored in time, it can serve as cleaning and cooling, and the temperature drops slightly, the small molten parts will fall off and will not expand to cause larger abnormal wear, causing severe damage to the cylinder wall, piston, and piston rings, showing a melting flow state on the cylinder wall surface, showing uneven irregular edge grooves and wrinkles. Compared to other types of wear, this is the most severe and destructive wear. For Japanese solenoid valves, pay attention to the following points: Before the solenoid valve linkage test, the process pipeline must be strictly blown and qualified. Pipelines that have not passed the blow must not be installed, as residual materials such as welding slag and dust in the pipeline will damage the valve core and valve seat sealing surface. Before the linkage, check that both ends of the valve should not have pressure testing or blocked blind flanges. For those with a handwheel mechanism, the handwheel mechanism should be in the 'released' position. Check if the supply air pressure meets the supply requirements of each. Economy: Many solenoid valves can be used universally, but on the basis of meeting the above three points, the most economical product should be selected. 4. Valves with the above characteristics, when approaching fully closed, the valve disc action accelerates,容易发生水锤(水的冲击压),接近全闭时,阀门动作越缓慢越好,因此可以在阀瓣上设置节流机构。The response frequency of the rotary clamping cylinder turning angle and response frequency; the main features and function description of the CLR linear/rotary clamping cylinder, the CLR linear/rotary clamping cylinder is suitable for various types of clamping actions. Through the combination of the linear and oscillating movements of the piston, rod, even workpieces outside the clamping range can be inserted and removed. The cylinder can be selected to swing left or right, in addition, the cylinder with a diameter of ? 40 CLR, the cylinder can also perform linear motion. Clamping fingers: can be ordered as an accessory, product advantages are diversified, easy to install, practical, simple mechanical system, sturdy structure, long service life, low initial installation and maintenance costs, new product: with dust and welding spatter protection CLR, adjustable swing direction, compact structure, requires very little installation space, the hole type conforms to ISO 21287 standard, therefore can use standard accessories in the range of foot brackets and flange mounting parts, the bearing cover and end cover use internal threads, making the cylinder installation simple, whether direct installation or using installation accessories, the clamping fingers, including the easy-to-install rubber cap for protecting sensitive surfaces, can be
Pneumatic gripper DHWS-32-A-NC belongs to the Clamping Jaws, Clamping Plates series under CKD company, model number DHWS-32-A-NC. To purchase or inquire about Pneumatic gripper DHWS-32-A-NC, you can directly contact 158 0047 0089 (Mr. He).
1. Cylinders: Used to convert the energy of compressed air into mechanical energy to produce linear motion.
2. Pneumatic valves: Used to control the direction, speed, and pressure of airflow, regulating the operation of pneumatic systems.
3. Pneumatic motors: Devices that convert compressed air into rotary motion.
4. Air tubes and connectors: Used to connect various components in pneumatic systems and transmit air.
Yes, CKD pneumatic components require regular maintenance to ensure normal operation and extend service life. Key maintenance points include:
- Regularly check and replace seals and gaskets to prevent air leakage.
- Inspect and clean filters to ensure clean air quality.
- Lubricate moving parts to reduce wear and improve efficiency.
- Check air tubes and connectors to ensure secure and undamaged connections.
When selecting the appropriate CKD pneumatic components, consider the following factors:
Application requirements: Understand the specific working environment and tasks, such as load, speed, and stroke.
Air source conditions: Ensure that the pressure and flow of the air source meet the component’s requirements.
Installation space: Confirm available space and choose components of suitable size.
Environmental factors: Consider the temperature, humidity, and potential corrosiveness of the working environment to select suitable materials and designs.
Common pneumatic system faults include:
Air leakage: Causes efficiency decline; check seals, connections, and tubes, find leak points, and repair or replace.
Stuck cylinder piston: Possibly caused by dirt or insufficient lubrication; clean the piston and add lubricant.
Valve failure: Check electrical control signals, ensure smooth airflow, and verify if the valve itself is damaged.
Insufficient pressure: Inspect air source pressure, filters, and piping to ensure no blockage or leakage.