Language
Home > CKD > Clamping Jaws, Clamping Plates
Pneumatic gripper HGPT-25-A-B

CKD Pneumatic gripper HGPT-25-A-B

Brand:CKD Model:HGPT-25-A-B

The festo pneumatic gripper HGPT-25-A-B is mainly affected by stray current interference in pipelines, strong electromagnetic wave interference in space, and magnetic field interference from large motors, etc. Stray current interference in pipelines can usually be satisfactorily addressed with good individual grounding protection. However, if exposed to strong stray currents (such as in electrolyt ...

The festo pneumatic gripper HGPT-25-A-B is mainly affected by stray current interference in pipelines, strong electromagnetic wave interference in space, and magnetic field interference from large motors, etc. Stray current interference in pipelines can usually be satisfactorily addressed with good individual grounding protection. However, if exposed to strong stray currents (such as in electrolytic workshop pipelines), the peak-to-peak AC voltage (Vpp) induced on the two electrodes can sometimes reach up to 1 counter, a simple introduction to the counter; the counter is installed in various pipeline systems to strictly prevent the backflow of media, protecting the media or equipment behind it from contamination. It consists of two series-connected check valves and a transition section, ensuring a tight seal to prevent any backflow of media. If one of the seals is damaged, the other still functions to prevent backflow. However, if both check valve seals are damaged simultaneously, the check function is lost, and the safety reliability is relatively poor, with a simpler working principle. Due to the difference in specific gravity between the core and the fiber filaments, the comet tail fibers spread out and swing with the backwash water flow, generating a strong dragging force; the mutual collision of the filter media also intensifies the mechanical force acting on the fibers in the water, and the irregular shape of the filter media causes them to rotate under the action of the backwash water flow and air flow, strengthening the mechanical shear force acting on the filter media during backwashing. The combined effect of these forces makes it easy for solid particles adhering to the surface of the fibers to fall off, thereby improving the cleaning efficiency of the filter media. Thus, the asymmetric fiber filter media also has the backwashing function of granular filter media. Notes on valve islands: 9, a cylinder with an outer jacket type sealing piston ring and a high-performance combined type sealing piston ring. Leakage in the swinging cylinder: leakage causes insufficient air pressure, making it difficult for the forced valve to open and close. The reason is that the sealing gasket is damaged or the sliding valve is worn, causing several cavities to leak air. When dealing with the electromagnetic valve failure of the switching system, the appropriate time should be chosen, and the maintenance should be carried out when the electromagnetic valve is de-energized. If the maintenance cannot be completed within a switching gap, the switching system can be paused for leisurely maintenance. ⑤ The diaphragm and lining should be regularly inspected to prevent corrosion and tearing from damaging other parts and causing accidents. Method of adding a gasket to the joint surface of the rotary clamping cylinder; if the local gap leakage at the joint surface of the rotary clamping cylinder is not very large, 80-100 mesh copper mesh can be used after heat treatment to lower its hardness, then cut into the appropriate shape, placed on the leakage site of the joint surface, and then matched with cylinder sealant. If the gap at the joint surface is large and the leakage is severe, a 50mm wide and 5mm deep groove can be opened on the upper and lower joint surfaces, and an IGr18Ni9Ti toothed gasket can be embedded in the middle. The thickness of the toothed gasket is generally 0.05-0.08mm thicker than the depth of the groove, and an equivalent shape stainless steel gasket can be used for adjustment. Electromagnetic valve blockage and discharge: when the valve is in the closed state, the upstream and downstream valve seats block the liquid, and the stagnant material in the valve chamber can be discharged through the discharge device. For an electromagnetic valve that cannot function normally, the first thing to do during maintenance is to clarify which part of the valve has a problem, and then targeted maintenance and replacement can be carried out. An electromagnetic valve generally mainly includes three major components: the pilot valve (pilot valve displacement sensor), the main valve (main valve core displacement sensor), and the integrated amplifier. In order to record the problems found,

Pneumatic gripper HGPT-25-A-B belongs to the Clamping Jaws, Clamping Plates series under CKD company, model number HGPT-25-A-B. To purchase or inquire about Pneumatic gripper HGPT-25-A-B, you can directly contact 158 0047 0089 (Mr. He).

FAQ

  • What is the basic function of CKD pneumatic components?
    CKD pneumatic components use compressed air as a power source to transmit and convert forces. They can be used to control machine movements, transmit force, or achieve automation. Common pneumatic components include cylinders, pneumatic valves, and pneumatic motors.
  • What are the main types of CKD pneumatic components?

    1. Cylinders: Used to convert the energy of compressed air into mechanical energy to produce linear motion.

    2. Pneumatic valves: Used to control the direction, speed, and pressure of airflow, regulating the operation of pneumatic systems.

    3. Pneumatic motors: Devices that convert compressed air into rotary motion.

    4. Air tubes and connectors: Used to connect various components in pneumatic systems and transmit air.

  • Do CKD pneumatic components require regular maintenance? If yes, what are the key points?

    Yes, CKD pneumatic components require regular maintenance to ensure normal operation and extend service life. Key maintenance points include:

    - Regularly check and replace seals and gaskets to prevent air leakage.

    - Inspect and clean filters to ensure clean air quality.

    - Lubricate moving parts to reduce wear and improve efficiency.

    - Check air tubes and connectors to ensure secure and undamaged connections.

  • How to choose the right CKD pneumatic components?

    When selecting the appropriate CKD pneumatic components, consider the following factors:

    Application requirements: Understand the specific working environment and tasks, such as load, speed, and stroke.

    Air source conditions: Ensure that the pressure and flow of the air source meet the component’s requirements.

    Installation space: Confirm available space and choose components of suitable size.

    Environmental factors: Consider the temperature, humidity, and potential corrosiveness of the working environment to select suitable materials and designs.

  • What are common faults in CKD pneumatic component systems and how to troubleshoot?

    Common pneumatic system faults include:

    Air leakage: Causes efficiency decline; check seals, connections, and tubes, find leak points, and repair or replace.

    Stuck cylinder piston: Possibly caused by dirt or insufficient lubrication; clean the piston and add lubricant.

    Valve failure: Check electrical control signals, ensure smooth airflow, and verify if the valve itself is damaged.

    Insufficient pressure: Inspect air source pressure, filters, and piping to ensure no blockage or leakage.